Casablanca-Settat, Morocco
info@gmdgroup.ma
0523 71 13 40
+212 6 68 62 77 56
ISO Certified
GMD Group — Non-Absorbable Sutures
Product range
Non-absorbable surgical sutures

Permanent strength,
engineered
to last.

Four specialized non-absorbable suture lines — each formulated for permanent wound support, cardiovascular surgery, and procedures requiring lasting tensile retention. Manufactured in Morocco to international standards.

Download catalog
4 Products
Non-absorbable suture lines
Permanent
Tensile strength retention
6-0 → 2
Complete size range
ISO 13485
Quality management certified
Product range
Each suture, in detail
Select a product tab to explore full specifications and clinical indications.
Damalon
01
Damalon
Polyamide · Monofilament
Damaster
02
Damaster
Polyester · Braided
Damasilk
03
Damasilk
Silk · Braided
Damalene
04
Damalene
Polypropylene · Monofilament
Product range
01
Damalon
02
Damaster
03
Damasilk
04
Damalene
Non-Absorbable · Monofilament
Damalon
Polyamide monofilament suture with high memory and excellent tensile strength
Damalon
Composition & construction
Composition
Polyamide (Nylon)
Construction
Monofilament
Coating
None — smooth monofilament surface minimises tissue drag and infection risk
Performance data
Tensile strength
Permanent retention
Absorption
Non-absorbable
Sterilization
Ethylene Oxide
Colour
Black
Tissue compatibility
High memory and flexibility. Monofilament structure provides excellent resistance to infection — no interstices for bacterial colonisation.
Tensile strength
Permanent
Non-absorbable — retains strength indefinitely
Colour & identification
Black
Easy identification during surgery
Available sizes
6-05-04-03-02-0012
Key features
  • Non-absorbable monofilament with high and ideal memory — returns to previous shape after deformation
  • Excellent tensile strength — does not extend during handling
  • High flexibility making it easy to use in complex procedures
  • Monofilament structure provides high resistance to wound infection
  • Remarkably smooth surface for easy tissue passage with minimal trauma
Indications for use

Indicated for general soft tissue approximation and ligation, including cardiovascular surgery and neurosurgery. Ideal for skin and surface closure such as epidermal and superficial wounds. Finer sizes used in ophthalmic and microsurgery procedures.

These details are intended for healthcare professionals. If you are a patient, please share the properties and effects of this product with your doctor.

Non-Absorbable · Braided
Damaster
Polyester braided suture with permanent tensile strength and silicon coating
Damaster
Composition & construction
Composition
Polyester
Construction
Braided
Coating
Silicon — reduces tissue trauma during passage and improves knot security
Performance data
Tensile strength
Permanent retention
Absorption
Non-absorbable
Sterilization
Ethylene Oxide
Colour
Green & Undyed
Tissue compatibility
Silicon coating lowers the possibility of tissue trauma. Excellent choice for procedures requiring permanent suture retention with high knot security.
Tensile strength
Permanent
Retains tensile strength permanently in vivo
Colour & identification
Green & Undyed
Available sizes
6-05-04-03-02-0012
Key features
  • Non-absorbable multifilament suture coated with silicon — reduces tissue trauma
  • Composed of polyester — an ester functional group polymer with excellent durability
  • Very practical handling — excellent choice for surgery requiring permanent suture
  • Permanently retains tensile strength — ideal for long-term tissue support
  • High knot security for reliable and lasting wound closure
Indications for use

Used in soft tissue approximation and ligation. Due to its unique properties, ideal for permanent and removable fixture surgeries such as implantation prostheses. Excellent choice for cardiovascular surgery, ophthalmic surgery, and face lift procedures.

These details are intended for healthcare professionals. If you are a patient, please share the properties and effects of this product with your doctor.

Non-Absorbable · Braided · Silk
Damasilk
Braided multifilament silk suture with silicon treatment for smooth tissue passage
Damasilk
Composition & construction
Composition
Natural Silk
Construction
Braided
Coating
Silicon — enhances smoothness and passage through tissue, minimising trauma during procedures
Performance data
Tensile strength
Loses most strength in ~1 year
Absorption
Classified non-absorbable
Sterilization
Ethylene Oxide
Colour
Black
Tissue compatibility
Elicits a minimal initial inflammatory reaction. Tight braiding technology ensures consistency. Not recommended for patients with known silk allergies.
Strength note
~1 year
Loses most tensile strength over approximately one year in vivo
Colour & identification
Black
Available sizes
6-05-04-03-02-0012
Key features
  • Sterilized non-absorbable braided multifilament surgical suture
  • Silicon treatment enhances smoothness and tissue passage, minimising trauma
  • Elicits minimal initial inflammatory reaction in tissues
  • Good tensile strength with tight braiding technology for consistency
  • Wide variety of surgical procedure applications
Indications for use

Indicated for general soft tissue approximation and ligation across a wide variety of surgical procedures. Should not be used where permanent tensile strength retention is required — such as fixation of intraocular lenses or synthetic vascular grafts — as gradual loss of tensile strength may occur over time in vivo. Not for use in patients with known allergies to silk.

These details are intended for healthcare professionals. If you are a patient, please share the properties and effects of this product with your doctor.

Non-Absorbable · Monofilament
Damalene
Polypropylene monofilament suture — inert, strong, ideal for cardiovascular and neurological surgery
Damalene
Composition & construction
Composition
Polypropylene
Construction
Monofilament
Coating
None — polypropylene is inherently inert with virtually no tissue reaction
Performance data
Tensile strength
Permanent retention
Absorption
Non-absorbable
Sterilization
Ethylene Oxide
Colour
Blue
Tissue compatibility
Virtually inert — tissue reaction almost non-existent. Does not cause tissue rupture and does not support infection during surgical procedures.
Tensile strength
Permanent
Retains strength permanently — no degradation in vivo
Colour & identification
Blue
Easy identification during surgery
Available sizes
6-05-04-03-02-0012
Key features
  • Sterilized non-absorbable monofilament with excellent high tensile strength
  • High softness and smoothness for easy passage through tissue with minimal trauma
  • Good knot security and easy knot placement
  • Virtually inert — tissue reaction almost non-existent
  • Does not cause tissue rupture and does not support infection
  • Blue colour for easy identification during surgery
Indications for use

Indicated for general soft tissue approximation and ligation, including cardiovascular surgery, ophthalmic surgery, plastic surgery, neurological procedures, and microsurgery.

These details are intended for healthcare professionals. If you are a patient, please share the properties and effects of this product with your doctor.

Side-by-side comparison
Compare all products
Filter by specification category. Highlight a column to focus your evaluation.
Highlight:
Damalon
Damalon
Damaster
Damaster
Damasilk
Damasilk
Damalene
Damalene
Specification Damalon Damaster Damasilk Damalene
Select any two products to compare
Get in touch
Request samples
or a clinical quote.
Our medical advisors are available to guide you to the right suture for your specialty and provide product samples on request.

GMD Group Footer
Scroll to Top